To calculate the relative centrifugal force at the given rotor speed and given rotor radius, please enter the values in the appropriate fields and press the Calculate.
Eppendorf 5415D & 5417R Centrifuges For access or consultation: Dr. Kim DeWeerd 591-8831 or The Molecular Core Facility has two refrigerated microfuges (5417R) and five microfuges without refrigeration (5415D). Purpose: A microfuge is a workhorse type of centrifuge used for a variety of separations in small volumes typical of Molecular Biology. The maximum centrifugal force in these centrifuges is 16,000 x g.
Specific Description: These centrifuges are equipped with fixed angle rotors that accommodate either 24 or 30 in non-refrigerated or refrigerated microfuges, respectively. The rotors can hold either 2.0 ml vials, 1.5 ml vials, 0.5 ml vials or 0.2 ml vials with adapters. For More Information: Instrument Photographs.
DESCRIPTION Eppendorf Refrigerated Microcentrifuge Model 5417 R Tried and trusted model: In many globally successful biotechnology companies, the Centrifuge 5417 R (refrigerated) was already present at the beginnings as part of the startup laboratory equipment. And nowadays they are still successfully doing their jobs. Reason enough for Eppendorf to bring the accessory and rotor program of these microliter centrifuges right up to date. The increasing range of applications will be fully covered, now and in the future.
For current users and for todays start-up companies. Exceptionally short centrifuge times can be achieved e.g. For Eppendorf reaction tubes with a relative centrifugal acceleration of 25,000 x g in the fixed-angle rotor.
The PCR strip rotor enables the centrifugation of 8-tube and 5-tube strips. And, as before, Eppendorf supplies a swing-bucket rotor for 1.5/2 ml reaction tubes and a 30-position fixed-angle rotor.
The new robust and high-temperature resistant aluminum lid and the optimized rotor detection ring means that the aerosol-tight version can be autoclaved in its entirety for up to 2 h at 140 °C to eliminate even prion contamination. The easy-to-read display and the practical soft keypad on both models enable simple and self-explanatory programming of all operating modes. With short acceleration and braking times at max.
Rcf and large capacities, the Centrifuge 5417 R cope even with high sample throughput in style. The Fast Cool function cools the 5417 R rapidly down to 4 °C, which is also maintained during centrifugation at maximum rotational speed. Afterwards, with standby cooling, the centrifuge remains at the required temperature. CM74 3 years ago 3 years ago I need to replace the main power switch on the right side of the unit. How is access best obtained for this? Remove the upper housing?
Or the front panel? FEATURES. Embossed foil keypad for simple operation. Fast Cool function: from room temperature to 4°C in approx. 15 min.
Short-spin function with preselected rotational speed. rpm or rcf settings as required (from 500 rpm in steps of 100 rpm).
Timer up to 99 min or continuous run. Soft key for gentle acceleration and deceleration. Temperature settings from -9 to 40°C. Sample temperature.